50kV VLF AC High Voltage Test Set Ultra Low Frequency Generator

50kV VLF AC High Voltage Test Set Ultra Low Frequency Generator

VLF High Voltage Generator Table 1 II.Features The product has features as follows: Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect...
انکوائری بھیجنے
Product Details of50kV VLF AC High Voltage Test Set Ultra Low Frequency Generator

 

Table 1

Model no

Rated Voltage/current

Load Carrying

Capacity

Power

FuseTube

Product Structure and Weight

HZDP-30K

30kV/20mA

(Peak)

0.1Hz, Less than or equal to 1.1µF

5A

Controller:4㎏

Booster: 25㎏

0.05Hz, Less than or equal to 2.2µF

0.02Hz, Less than or equal to 5.5µF

HZDP-50K

50kV/30mA

(Peak)

0.1Hz, Less than or equal to 1.1µF

15A

Controller:4㎏

Booster: 50㎏

0.05Hz, Less than or equal to 2.2µF

0.02Hz, Less than or equal to 5.5µF

HZDP-80K

80kV/30mA

(Peak)

{{0}}.1Hz, Less than or equal to 0.5µF

20A

Controller:4㎏

Booster Grade 1(30kV):25㎏

Booster Grade 2(50kV):50㎏

0.05Hz, Less than or equal to 1µF

0.02Hz, Less than or equal to 2.5µF

vlf ac hipot tester

II.Features

The product has features as follows:

Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms.

Overcurrent protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.

A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

III.Tech Data

1. Rated output voltage: See Details of Table 1

2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

3. Measurement accuracy: 3 percent

4. Positive and negative voltage peak errors:   Less than or equal to 3%

5. Voltage wave form distortion: Less than or equal to 5%

Huazheng Electric Manufacturing

Customer Visit

Case

ڈاؤن لوڈ، اتارنا ٹیگ: 50kV VLF AC High Voltage Test Set Ultra Low Frequency Generator, China, suppliers, manufacturers, price, for sale, VLF High Voltage Generator, VLF High Voltage Test Set, ac high voltage breakdown tester, Ultralow-frequency high voltage generator, vlf hipot test 50 kv, very low frequency cable testing, hipot generator, Vlf AC/DC High Voltage Tester 50kv, 13.8kv VLF withstand test